UPS Backup Time Calculator Pakistan

Free UPS backup time calculator for Pakistan — battery Ah, load and inverter efficiency to backup hours. No sign-up.

Free · No sign-up · Runs in your browser — nothing is uploaded

Battery and load in, backup time out — how long your UPS lasts in a power cut.

Ah
%

Your load — tick appliances (typical watts)

Watts are typical values for Pakistani homes. Use the count buttons to add more than one of anything, or add extra watts below.

Ceiling fan · 75W

2

Pedestal fan · 60W

0

LED bulb · 12W

4

LED TV 32-inch · 60W

0

LED TV 43-inch · 100W

1

Fridge · 150W

Running watts — the compressor cycles on and off

0

Laptop · 65W

0

Wi-Fi router · 10W

1

Energy saver bulb · 23W

0
W

Total load: 308 W (appliances 308 W)

Estimated backup time

3 h 19 min

1,020 Wh usable from a 12V 200Ah lead-acid battery at 308 W load

What the recharge costs you on the bill

Recharging this battery draws about 42 units a month from the wall (estimate, at 30 recharges a month). A home that used 200 units or less in each of the last six months keeps the protected tariff — Rs 10.54 a unit for 1 to 100 units, Rs 13.01 for 101 to 200. One month over 200 units and the account loses protected status for about six months.

Formula checked 18 Nov 2026. This is an estimate, not a guarantee — real backup varies with battery age, temperature and the actual load. Rates: NEPRA protected tariff per S.R.O. 279(I)/2026.

How to use

  1. Pick your battery type, voltage and size — lead-acid gives 50% usable capacity, lithium 90%.
  2. Tick your appliances (typical watts) or add extra watts — your backup time appears instantly.
  3. Switch to Battery size needed mode to find the Ah you need for the hours you want.

Formula

Backup hours = (Voltage × Ah × Depth of discharge × Inverter efficiency) ÷ Load. Lead-acid DoD 50%, lithium 90%, inverter efficiency 85%.

Example

12V 200Ah lead-acid battery at 400W load: 12 × 200 × 0.50 × 0.85 = 1,020 Wh → 1,020 ÷ 400 = 2 h 33 min. Reverse: 500W for 4 hours needs 392 Ah.

FAQ

How long will my UPS last on one battery?

It depends on the battery size, the battery type, and the load. A 12V 200Ah lead-acid battery at 400W gives about 2 h 33 min, because only half the rated capacity is usable (50% depth of discharge) and the inverter loses about 15% as heat. A lithium battery of the same size lasts almost twice as long — 90% of its capacity is usable.

What battery size do I need for 4 hours backup?

Switch to the Battery size needed mode, enter 4 hours and your load. For 500W on lead-acid that works out to 392 Ah — two 200 Ah batteries in parallel, or a 24V 200 Ah bank. On lithium the same 4 hours at 500W needs about 204 Ah.

Why does my UPS give less backup than the shop promised?

A 200 Ah battery holds 2,400 Wh on paper (12V × 200 Ah), but only about 1,020 Wh is usable after the 50% depth-of-discharge limit and 85% inverter efficiency. Shop figures usually quote the paper number and ignore both losses — and an old battery holds less still.

Does UPS charging increase my electricity bill?

Yes. A full recharge of a 200 Ah battery draws about 2.8 kWh from the wall. Recharged daily at half discharge that is about 42 units a month, at full discharge about 85 units — enough on its own to push a home over 200 units and cost protected status for about 6 months. Enter your monthly units in the tool to see the warning.

Lead-acid or lithium for home UPS?

Lithium (LiFePO4) gives 90% of its capacity against 50% for lead-acid, lasts many more charge cycles, and is much lighter — but costs more upfront. For the same backup hours you need a much smaller lithium battery, so compare the price per usable Wh, not per Ah.